Professional Calibration Services Cairns

Complete calibration services for your critical equipment across North Queensland.

Our specialized laboratory ensures measurement accuracy and regulatory compliance for electrical testing equipment, gas detection systems, pressure instruments, torque tools, temperature measurement devices, and dimensional equipment.

Bennic Calibration provides comprehensive instrument calibration services for industries throughout Cairns and North Queensland. Our facility delivers calibration results traceable to Australian national measurement standards, in accordance with Australia's national measurement framework, keeping your operations compliant and safe.

  • Who we help

Industries We Serve

From remote mine sites to Cairns workshops. If your work depends on accurate measurement, we keep you compliant.

Submit Your Equipment

Drop off your equipment at our Cairns laboratory. We handle all instrument types with care and log everything in on arrival.

We Calibrate & Test

Our technicians calibrate your instruments using reference equipment calibrated by NATA-accredited laboratories, with full documentation of results.

Receive Your Certificate

Get your calibrated equipment back with a digital calibration certificate, ready for audits, compliance, and ongoing use.

  • Who we help

Industries We Serve

From remote mine sites to Cairns workshops. If your work depends on accurate measurement, we keep you compliant.

Mining & Resources

Gas detection, pressure, and electrical calibration for safe mine site operations.

Electrical Contractors

AS/NZS 3760 compliant PAT, RCD, multifunction, and insulation tester calibration.

Food & Cold Chain

Temperature probe and thermometer calibration for HACCP and food safety compliance.

Environmental & Lab

Dimensional, humidity, and measurement instrument calibration for accredited labs.

Manufacturing

Torque, dimensional, and pressure calibration to keep production lines within spec.

Automotive & Workshop

Torque wrench and tyre pressure gauge calibration for workshops and service centres.

Electrical Testing Equipment

Professional calibration services for all electrical testing and measurement instruments, ensuring compliance with key Australian and Queensland standards.

Ensuring Compliance & Safety

Our calibration services are performed to meet manufacturer specifications and keep you compliant with standards and regulations, including AS/NZS 3760, AS/NZS 3000, the Queensland Electrical Safety Act 2002, and the Queensland Electrical Safety Regulation 2013.

Instruments We Calibrate

  • Digital & Analog Multimeters - DC/AC voltage, current, and resistance
  • Insulation Testers - High voltage insulation resistance
  • RCD Testers - Residual current device safety verification
  • Multifunction Testers - Comprehensive testing for electrical installations
  • Process Calibrators - Simulation and measurement of process signals
  • PAT Testers - Appliance safety and compliance testing
  • Clamp Meters - Non-contact AC/DC current measurement
  • Earth Resistance Testers - Grounding and earth electrode resistance
  • Micro Ohm Meters - Low resistance measurement for contacts and cables
  • DC Power Supplies - Voltage and current source accuracy
  • Power Quality Analyzers - Data logging and power consumption analysis
  • Tachometers - Non-contact and contact speed measurement

Applications:

Electrical maintenance, safety testing, power systems, industrial automation, and quality control

Temperature Measurement

Accurate temperature calibration services for process monitoring and environmental applications.

Calibration Standards

Our temperature calibrations are performed in accordance with the following international standards:

IEC 60584: Thermocouples
IEC 60751: RTDs

Instruments We Calibrate

  • Thermometers - Digital and analog temperature measurement
  • Temperature Probes - RTD, thermocouple, and thermistor sensors
  • Infrared Thermometers - Non-contact temperature measurement
  • Temperature Transmitters - Process control temperature devices
  • Thermal Cameras - Infrared thermal imaging equipment

Range

-20°C to 600°C

Applications

Process monitoring, HVAC, food safety, environmental

Gas Detection Systems

Professional calibration for gas detection and monitoring equipment. Gas detector calibration is critical. A miscalibrated instrument in a confined space or hazardous area can put lives at risk.

Instruments We Calibrate

  • Fixed Gas Detectors - Permanent installation monitoring systems
  • Portable Gas Monitors - Personal and area gas detection devices
  • Multi-Gas Detectors - Combined gas monitoring instruments
  • Oxygen Analyzers - O2 concentration measurement devices
  • Combustible Gas Detectors - LEL/LFL monitoring equipment
  • Toxic Gas Sensors - H2S, CO, and other hazardous gas detection

Applications

Confined space entry, industrial safety, environmental monitoring

Torque Services

Ensure precision and compliance with professional torque calibration services.

Our laboratory specializes in torque wrench calibration and torque screwdriver calibration, adhering to ISO 6789:2017 standards for guaranteed accuracy across a 0.5 Nm to 1,500 Nm range.

Torque Tools We Calibrate

  • Click Torque Wrenches - Mechanical and digital click-type tools
  • Electronic Torque Wrenches - Digital display and data logging
  • Beam Torque Wrenches - Deflecting beam and dial indicators
  • Torque Screwdrivers - Precision assembly and electronics

Trust Bennic for torque calibration that optimizes safety, efficiency, and compliance in automotive, aerospace, and manufacturing sectors.

Pressure Services

Our pressure calibration facility handles everything from delicate vacuum measurements to high-pressure industrial applications, calibrated to MSA Test Methods with results traceable to national measurement standards.

Capabilities

Max Pressure: 100,000 kPa
Vacuum: Down to -95kPa

All types: gauge, absolute, vacuum, differential

Test Media

Nitrogen Gas
Compressed Air
Demineralized Water
Mineral Oil

Electronic Instruments (MSA Method 1)

  • Pressure Calibrators – High-accuracy digital instruments (<0.1% reading)
  • Pressure Indicators – Digital displays (>0.1% full scale)
  • Pressure Transducers – Convert pressure to electrical outputs

Mechanical Gauges (MSA Method 2)

  • Test Gauges - Precision reference standards (≤0.25% accuracy)
  • Industrial Dial Gauges - Standard process gauges (≥0.3% accuracy)
  • Vacuum & Compound Gauges - Spanning vacuum to positive
  • Differential Pressure Gauges - Two port pressure differencing
  • Backflow Test Kits - Water backflow prevention devices (±2 kPa)

Dimensional Measurement

Precision calibration for manufacturing and quality control instruments.

Dimensional Tools

  • Vernier Calipers: precision length measurement
  • Micrometers: high-accuracy dimensional measurement
  • Dial Gauges: mechanical measurement indicators

Applications

Manufacturing, quality control, precision machining

Other Instruments

Professional calibration services for a variety of specialized measurement and assessment equipment.

  • Sound Level Meters - Noise measurement and monitoring equipment
  • Anemometers - Airflow and wind speed measurement tools
  • Humidity Meters - Environmental moisture and dew point assessment
  • Scales & Balances - Industrial and laboratory weighing equipment

Breathalyser Calibration

Professional calibration services for alcohol detection and measurement devices, with a focus on Andatech brand breathalysers.

Calibration Standard

All breathalyser calibrations are performed in accordance with the Australian standard AS3547:2019, using certified reference equipment to help ensure accurate readings and reliable performance.

Calibration Interval

Every 6 months (26 weeks) or after 1,000 tests, whichever comes first, in line with Australian Standards requirements.

Device Coverage

Handheld breathalyzers
Wall-mounted workplace alcohol testers

High Voltage Testing

Our highly trained technicians provide comprehensive testing and inspection services for all your electrical Personal Protective Equipment (PPE), insulated tools, and high voltage safety equipment, ensuring compliance with Australian safety standards for safe workplace operations.

Testing Standards & Compliance

  • AS 2225 – Electrical Insulating Gloves and Sleeves
  • AS 2978 – Electrical Insulating Mats and Blankets
  • AS 5804 – Electrical Insulating Sticks, Covers, and Barriers
  • AS/NZS IEC 61111 – Live working - Electrical insulating matting
  • Manufacturer testing recommendations
  • Workplace Health & Safety regulations

Electrical Insulating PPE

  • Insulating Gloves
  • Insulating Sleeves
  • Blankets & Covers
  • Low & HV Insulating Mats
  • Low Voltage Rescue (LVR) Kits

Insulated Tools

  • Tel-O-Poles & Operating Rods
  • Link Sticks & Tiger Tails
  • Hard Covers & Insulating Guards
  • Shot Gun Sticks
  • Insulated Hand Tools

HV Detection & Safety

  • Portable Earthing Devices
  • High Voltage Detectors
  • Voltage Indicators
  • Phase Sequence Testers

Risk Reduction

Properly tested equipment reduces the risk of electrical incidents and workplace accidents

Regulatory Compliance

Meet your legal obligations for electrical equipment testing

Reliable Record-Keeping

Secure database storage with automated retest reminders so you never miss a deadline

Professional Certification

Clear documentation for all tested equipment supporting your safety management systems

  • Get Started Today

Ready to Book Your Calibration?

Contact our team today. Whether you need a single instrument or a full fleet of equipment calibrated, we're here to help keep your operations accurate, safe, and compliant.